What derating means
Derating means using a component below its rated limits so that it lasts longer and survives the worst case. It is usually written as a fraction of a rated value:
V_allowed = (1 − d) × V_reference
d is the derating fraction. 20 % derating means operating at no more than 80 % of the reference, so a 10 V reference allows 8 V.
Always state the reference. A percentage of the rated voltage is not the same as the same percentage of the category voltage at a high temperature, and when two limits apply, the more restrictive one wins.
Step 1: find the real worst-case stress
Derating starts from the worst-case stress, not the nominal value. For a capacitor the working voltage is the DC bias plus the AC ripple plus any transient peaks, and that sum must stay within the rating. For a supply input, use the top of the specified operating range, not the nominal voltage: an industrial controller with a 24 V nominal input specified for 18 to 32 V is checked at 32 V, and its surge protection is designed for the surge test level on top of that.
Step 2: check the voltage rating
A simple and common way to express a voltage check is the margin of the rating over the worst case:
margin = V_rated / V_worst-case − 1
| Rated voltage | Margin over 32 V | Against a 25 % policy |
|---|---|---|
| 40 V | 25.0 % | Meets the policy |
| 36 V | 12.5 % | Below the policy |
| 35 V | 9.4 % | Far below: little room for any transient |
Solid tantalum capacitors (MnO2) are a well-documented case. Vishay's technical note 40246 says the application (working) voltage is usually recommended to be between 0.6 and 0.5 of the rated voltage, in line with EIA-809 and relevant NASA and military specifications, and recommends an even higher derating for ratings of 35 V and more. Its table for use below 85 °C gives, for example:
| Voltage rail | Capacitor voltage rating |
|---|---|
| ≤ 3.3 V | 6.3 V |
| 5 V | 10 V |
| 12 V | 25 V |
| 15 V | 35 V |
| 24 V | 50 V or a series configuration |
Temperature lowers the voltage a capacitor can take. For the 293D / TR3 / TP3 series and similar, the same note says the maximum working voltage equals the rated voltage from −55 °C to +85 °C and then decreases linearly to 2/3 of the rated voltage at +125 °C; above +85 °C this is called the category voltage.
V_category(T) = V_rated × (1 − (T − 85 °C) / 40 °C × 1/3), for 85 °C ≤ T ≤ 125 °C
a straight-line reading of that curve. Example: a 10 V part at 105 °C allows 10 × (1 − 20/40 × 1/3) = 8.33 V. Use the curve in the datasheet of your series.
Step 3: check the current rating
Current derating keeps the continuous load below a fraction of the rated current. With a policy of 80 %, the required rating follows directly:
I_rated ≥ I_load,max / 0.8
example: a 1.2 A worst-case load needs a part rated for at least 1.5 A.
Use the worst-case load: all loads on at once, at the lowest input voltage for a converter (where its input current is highest), and the peak current for parts limited by peaks rather than averages.
Step 4: check the junction temperature
For a semiconductor the limit is the junction temperature. The usual first estimate is:
T_J = T_A + R_θJA × P_D
Texas Instruments' application note SPRA953D calls the use of R_θJA for this a misapplication: R_θJA is measured on a standard JEDEC test board, where in still air almost 70 % to 95 % of the power leaves through the board, and a real board rarely resembles it. Use it for a first screening and to compare packages, then confirm on the real board, for example with the ψ_JT or ψ_JB parameters the same note describes and a measured case or board temperature.
A linear regulator shows why this matters. TI's application report SLVA079 gives the regulator's dissipation as P_D = (V_I − V_O) × I_O and the limit as P_D(max) = (T_J,max − T_A) / R_θJA, and uses 285 °C/W for a 5-terminal SOT-23 package as its example.
| Quantity | Value |
|---|---|
| Dissipation P_D = (5 − 3.3) × 0.15 | 0.255 W |
| Temperature rise R_θJA × P_D | 72.7 °C |
| Estimated junction temperature 50 + 72.7 | 122.7 °C |
| Margin to a 125 °C maximum | 2.3 °C |
| Maximum dissipation for T_J ≤ 110 °C: (110 − 50) / 285 | 0.21 W |
A margin of 2.3 °C is not a design: lower the input voltage, spread the heat with copper, choose a package with better thermal performance or use a switching regulator. The ground (quiescent) current adds V_I × I_Q to the dissipation; SLVA079 defines it as the difference between the input and the output current.
Where derating policies come from
There is no single derating table for every product. Companies write their own policy from their reliability targets, their industry and the manufacturers' guidance, and stricter fields such as aerospace and defence use stricter limits. Whatever the policy, write it down, state the reference of every percentage and apply it the same way to every part.
The MithraTiny Component Selector Agent applies a policy per application domain. Its default checks a 25 % voltage margin, 80 % of the rated current and a junction temperature at least 15 °C below the maximum; for aerospace and defence it uses 50 %, 70 % and 25 °C, and for automotive it requires AEC-Q qualified parts.
Checklist
- The worst-case stress is used: top of the input range, ripple and transients, all loads on
- Every derating percentage states its reference (rated or category value)
- Capacitor voltage derating follows the manufacturer's guidance for the technology and temperature
- Continuous current stays below the policy fraction of the rating
- Junction temperature is estimated with the real dissipation and confirmed on the real board
- The derating policy is written down and applied to every part the same way
Do it faster with MithraTiny Component Selector Agent
From board requirements to a schematic-ready main active component recommendation, with derating checks and risks.
Sources
- Solid Tantalum Capacitors (With MnO2 Electrolyte) Voltage Derating, Technical Note. Vishay Intertechnology, Document number 40246, revision 07-Sep-2022.
- Semiconductor and IC Package Thermal Metrics, Application Note. Texas Instruments, SPRA953D, December 2003, revised March 2024.
- Understanding the Terms and Definitions of LDO Voltage Regulators, Application Report. Texas Instruments, SLVA079, October 1999.